Technical Characteristics of the Swimming Pool Option Heat Pump (PAC-RMP)

For the house heating capacity - see the "PAC-RM" house heating Heat Pump characteristics* sheet.

  Unité RMP10 RMP12 RMP16T RMP21T
SWIMMING POOL Volume 40 to 70 70 to 100 90 to 130 130 to 180
Pool Heating output Watt 11 500 14 950 18 400 22 700
Power Input Watt 2 483 3 180 3 755 4 540
C.O.P   4,6 4,7 4,9 5,0
Power Supply Volt 230/1/50Hz 400/3/50Hz
Water Flow m³/h 4,5 6,0 7,0 8,0
Fluid HFC R410A
Hydraulic Connection Pouces 3-piece coupling to connect up (supplied)
Loss of charge mCE 0,5 0,7 0,7 0,7
House heat exchanger Stainless Steel 316L
Bodywork + Fittings Stainless Steel 304L
Weight Kg 105 108 137 142
Height/Length/Width (with feet) mm 815/1100/455 1120/1100/455
Noise/acoustic level at 10m dBA 41 42

Cooling power output provided on request

*The values seen above relate to testing with the following conditions:

HEATING Mode COOLING Mode
  • Exterior air temperature: +15°C
  • Entry water temperature: 20°C
  • Hygrometry/Humidity: 80%
  • Exterior air temperature: +35°C
  • Entry water temperature: +23°C

Functional range - limitations:

COOLING Mode
  • Exterior air temperature: -10°C / +35°C
  • Maximum exit water temp: +32°C
  • Minimum exit water temp: +20°C