 *based on A7/W35 conditions Unit RM10 RM12 RM16T RM21T
Estimated house surface 80 to 115 115 to 130 135 to 190 190 to 270
House heating output Watt 9 850 12 775 15 700 19 300
House cooling output Watt 8 100 10 700 13 300 16 400
Power Input Watt 2 291 2 903 3 651 4 595
C.O.P   4,3 4,4 4,3 4,2
Electrical Power Supply Volt 230/1/50Hz 400/3/50Hz
Max Current A 24 28 12,2 15
Water Flow m³/h 1,7 2,2 2,7 3,3
Fluid HFC R410A
Hydraulic Connection Inches 1"(26x34)
House heat exchanger Stainless steel 316L
Bodywork + Fittings Stainless steel 304L
Weight Kg 100 103 132 137
Height/Length/Width (with feet) mm 815/1100/455 1120/1100/455
Noise/acoustic level at 10m dBA 41 42

*The values seen above relate to testing with the following conditions:

HEATING mode COOLING mode
  • Exterior air temp. : +7°C(DB)6°C
  • Entry water temp. : 30°C
  • Exit water temp.  : 35°C
  • Exterior air temp: +35°C
  • Exit water temp for floorboard heating : +18°C
  • Exit water temp for air-convection system : + 7°C

Functional range - limitations :


HEATING mode COOLING mode
  • Exterior air temp.: -15°C / +35°C
  • Maximum exit water temp.: +55°C
  • Minimum exit water temp.: +25°C
  • Exterior air temp.: +18°C / +43°C
  • Maximum exit water temp.: +25°C
  • Minimum exit water temp.: +5°C

Read more about...
The qualities of heat pump design and construction for our range of heat pumps.
The pool heating heat-pump option - the PAC-RMP range of heating pumps.
The PAC-RMP swimming pool heating option - the configuration of the heat pump.
Hot water producing heat-pumps - the PAC-65 range of heat pumps.
The PAC-65 model - our hot water producing heat pump characteristics and contact us for your heat pump requirements.