Heat Pump Water heating at 65°C
Technical Characteristics of the PAC 65°C range, or return to the heat-pump general description.
| *according to A7/W35 conditions |
Unité |
PAC65-13M |
PAC65-13T |
PAC65-18T |
PAC65-24T |
PAC65-48T |
| House heating output |
Watt |
13 100 |
13 000 |
18 500 |
24 000 |
48 000 |
| Power Input |
Watt |
3 195 |
3 095 |
4 512 |
5 714 |
11 163 |
| C.O.P |
|
4,1 |
4,2 |
4,1 |
4,2 |
4,3 |
| Power Supply |
Volt |
230/1/50Hz |
400/3/50Hz |
| Max Current |
A |
31 |
13 |
15 |
19 |
32 |
| Water Flow |
m³/h |
1,4 |
1,4 |
2 |
2,6 |
8,4 |
| Fluid |
HFC |
R407C |
| Hydraulic Connections |
Pouces |
1"(26x34) |
1"1/2(26x34) |
| House heat exchanger |
Stainless Steel |
316L |
| Bodywork + Fittings |
Stainless Steel |
304L |
| Weight |
Kg |
137 |
137 |
140 |
206 |
350 |
| Height/Length/Width (with feet) |
mm |
1120 / 1100 / 455 |
1950/1400/700 |
| Noise/acoustic level at 10m |
dBA |
41 |
43 |
49 |
*The values seen above relate to testing with the following conditions:
Test conditions :
- Dry entry air temperatures: +7°C
- Humid entry air temperaturer: +6°C
- Entry water temperature: 27°C
- Exit water temperature: 35°C
|
Functional range - limitations :
- Exterior air temperature : -15°C / + 35°C
- Maximum exit water temp. : +65°C
- Minimum exit water temp : +25°C
|